Rsoft Cad Manual [extra Quality] (2025)
The interface supports simultaneous multi-pane views, including X, Y, Z, and rotatable 3D perspectives Import/Export Capabilities: Users can import mask files in GDS-II, DXF, and CIF formats and export designs for mask fabrication. 2. Integrated Material Management
Used for gratings, meta-surfaces, and photonic crystal structures to simulate an infinite array. 7. Troubleshooting Common RSoft CAD Layout Errors Symptom / Error Root Cause Corrective Action Discontinuous fields at waveguide junctions. Objects are not perfectly touching in space.
The RSoft CAD (Computer-Aided Design) environment is the foundational user interface for Synopsys’ RSoft Photonic Device Tools. It serves as the central hub for designing, simulating, and analyzing photonic devices, ranging from simple waveguides to complex photonic integrated circuits (PICs). The RSoft CAD Manual is the primary reference document for unlocking the full potential of this simulation suite. rsoft cad manual
' RSoft CAD Script Example (from Manual Chapter 18) Dim cad Set cad = GetObject(,"RSoftCAD.Application") cad.OpenFile "C:\MyDesign.ind" For width = 0.4 To 2.0 Step 0.1 cad.SetParameter "wg_width", width cad.RunSimulation cad.ExportData "Results\width_" & width & ".txt" Next
This comprehensive manual provides the essential workflows, execution steps, and advanced techniques needed to master the RSoft CAD environment. 1. Introduction to the RSoft CAD Interface The RSoft CAD (Computer-Aided Design) environment is the
: The manual emphasizes the difference between the User Coordinate System (UCS) and the absolute system. Mastering this early prevents "disjointed" components in your simulation.
Save your .ind design files before running large automated parameter sweeps to prevent data loss in case of an unexpected system interruption. w_mmi = 6.0
RSoft CAD uses a parameter-driven approach to geometry creation. Instead of drawing shapes with static pixel coordinates, you define shapes using variables linked to the Symbol Table. Component Types
Step-by-Step: Drawing a MMI (Multimode Interferometer) Splitter Set w_in = 0.5 , w_mmi = 6.0 , l_mmi = 45.0 .
Once the CAD model is built, you select a "simulation engine" (e.g., FDTD, BPM) from within the same interface to perform analysis without redrawing the structure. ИСОИ РАН Typical Manual Structure
Instead of entering 3.2 for a waveguide width, define a variable named w_core in the Symbol Table. If you change w_core later, every geometric object referencing that symbol updates automatically. Mathematical Expressions